1. Gyanastra
  2. Digital Logic
  3. Registers and Counters
  4. Synchronous vs Asynchronous Counters: Comparison Points
Free lesson, no account needed 4 min read 8 practice questions after it
Asked in past papers4 times
  • GATE CSE1991
  • ISRO2017
  • UGC NET20162010

Digital Logic · Registers and Counters

Synchronous vs Asynchronous Counters: Comparison Points

Overview

Counters provide accurate timing and control signals: they count clock pulses and assign each clock (count) to one device, and they are used in control-oriented applications.
Counters come in two types, synchronous and asynchronous, which differ mainly in how the clock is applied to the flip-flops. These comparison points are important for answering theory questions.

Key concepts

  • Counter: a circuit that provides accurate timing and control signals. Timing means counting the clock pulses and assigning each clock (count) to one device; control signals are used in control-oriented applications.
  • Synchronous counter: all the flip-flops respond to the same clock instances. If there are several devices (flip-flops), all of them receive the same clock simultaneously.
  • Asynchronous counter: the output of one flip-flop drives the clock of the next flip-flop (ripple clocking).
  • Shift counter: the simplified version of a synchronous counter. It holds some information and moves it to the next stage, that stage moves to the next one, and so on — this is called shifting.
    Shift counters are also useful in implementing the shift operations of registers.
  • Ring counter and Johnson counter: kinds of shift counters.
  • Flip-flops used: the basic element of a shift counter is the D flip-flop. Generally, two flip-flops are majorly used, T and D, because they have only one input (T or D).

How it works

  1. In a synchronous counter, the same clock is applied to all flip-flops at the same time, so there is no ripple delay.
  2. In an asynchronous counter, the signal must come out of one device, become the input of the next device, come out of that device, and so on — it has to ripple through all the devices.
  3. Because of the ripple chain, the asynchronous counter is slower than the synchronous counter.
  4. Because of simplicity of design (very easy to design), asynchronous counters are used in IC (Integrated Circuit) fabrication.
  5. Shift counters shift information from one stage to the next and are used for register shift operations.

Comparison

PointSynchronous counterAsynchronous counter
ClockingAll flip-flops respond to the same clockOutput of one flip-flop drives the clock of the next flip-flop
SpeedFaster (signal applied to all flip-flops at the same time)Slower (signal must ripple through all devices)
Design—Simple to design, hence used in IC fabrication
Commonly used flip-flopD flip-flopT flip-flop

Revision summary

  • Synchronous means a common clock to all flip-flops, which makes it fast; asynchronous means ripple clocking, which makes it slow.
  • The asynchronous counter's slowness comes from the signal rippling through all the devices.
  • Asynchronous counters are used in IC fabrication because they are simple to design.
  • A shift counter is the simplified version of a synchronous counter; its basic element is the D flip-flop.
  • D flip-flop is used in synchronous counters; T flip-flop is used in asynchronous counters; both have only one input.
  • Ring and Johnson counters are kinds of shift counters.
  • Shortcut: these comparison points are the key to answering theory questions on counters.

Previous-year exam insights

  • The main advantage of synchronous over asynchronous sequential circuits is ease of avoiding problems due to hazards (and faster operation); asynchronous circuits are cheaper/simpler in hardware but suffer from ripple delay and hazards.
    Asked inGATE 1991ISRO 2017UGC NET 2010
  • In a synchronous counter all flip-flops are clocked simultaneously, so the maximum clock frequency is limited only by the clock-to-output delay plus combinational (AND/decoder) delay of one stage, not by the number of flip-flops; in an asynchronous counter the propagation delay accumulates (n × tpd for n stages), so its maximum frequency falls as the count length grows.
    Asked inGATE 1991ISRO 2017
  • Asynchronous (ripple) counters are simpler and need fewer components (no common clock distribution or decoding logic), so they have lower hardware requirement; synchronous counters need more logic but are faster and hazard-free.
    Asked inISRO 2017UGC NET 2010
  • A modulus-N (divide-by-N) counter has N distinct states and needs at least ⌈log⁡2N\log_{2} N⌉ flip-flops; a ripple counter with n flip-flops naturally divides by 2n2^{n}, and a modulus less than 2n2^{n} is obtained by resetting/clearing on the desired state.
  • Ring counter: a circular shift register with one '1' circulating, giving modulus equal to the number of flip-flops (n states); Johnson (twisted-ring) counter feeds back the complement of the last stage, giving 2n states.
    Both are synchronous shift counters.
  • Synchronous counters can be designed with T flip-flops by making T = 1 for the LSB and T = AND of all lower-order flip-flop outputs for each higher stage;
    this gives a self-starting binary up-counter with no ripple delay.
Pages 1–2 of 2